Energy Performance Certificate

23, Orwell Close, UB3 1RL

EPC Report

Energy rating

Current: 63 D | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 61 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 73 Potential: 73
Field Value
LMK KEY 0761-2899-6030-9726-8271
ADDRESS1 23, Orwell Close
ADDRESS2
ADDRESS3
POSTCODE UB3 1RL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2016-07-21
LOCAL AUTHORITY E09000017
CONSTITUENCY E14001276
COUNTY
LODGEMENT DATE 2016-08-11
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 281
ENERGY CONSUMPTION POTENTIAL 201
CO2 EMISSIONS CURRENT 2.7
CO2 EMISS CURR PER FLOOR AREA 47
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 42
HEATING COST CURRENT 440
HEATING COST POTENTIAL 248
HOT WATER COST CURRENT 191
HOT WATER COST POTENTIAL 191
TOTAL FLOOR AREA 56
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Ground source heat pump, radiators, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 8.1
FLOOR HEIGHT 2.55
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23, Orwell Close
LOCAL AUTHORITY LABEL Hillingdon
CONSTITUENCY LABEL Hayes and Harlington
POSTTOWN HAYES
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2016-08-11 12:59:00
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100021432612
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000007
Address display
Nation ew