Energy Performance Certificate

The Laurels, Lower Crescent, Minster Lovell, OX29 0SD

EPC Report

Energy rating

Current: 61 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 65 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 80 Potential: 80
Field Value
LMK KEY 0758-1079-6249-5225-1990
ADDRESS1 The Laurels
ADDRESS2 Lower Crescent
ADDRESS3 Minster Lovell
POSTCODE OX29 0SD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2015-01-05
LOCAL AUTHORITY E07000181
CONSTITUENCY E14001591
COUNTY
LODGEMENT DATE 2015-01-14
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 164
ENERGY CONSUMPTION POTENTIAL 89
CO2 EMISSIONS CURRENT 7.4
CO2 EMISS CURR PER FLOOR AREA 28
CO2 EMISSIONS POTENTIAL 4.0
LIGHTING COST CURRENT 105
LIGHTING COST POTENTIAL 105
HEATING COST CURRENT 2282
HEATING COST POTENTIAL 1960
HOT WATER COST CURRENT 265
HOT WATER COST POTENTIAL 157
TOTAL FLOOR AREA 267
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE triple glazing
GLAZED AREA More Than Typical
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully triple glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 350 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Ground source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Laurels, Lower Crescent, Minster Lovell
LOCAL AUTHORITY LABEL West Oxfordshire
CONSTITUENCY LABEL Witney
POSTTOWN WITNEY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-01-14 09:19:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 30
LOW ENERGY FIXED LIGHT COUNT 30
UPRN 100120970935
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display