Energy Performance Certificate

60, Edinburgh Road, CW12 3EN

EPC Report

Energy rating

Current: 37 F | Potential: 60 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 F Current: 37 F 60 D Potential: 60 D

Environmental impact (CO₂)

Current: 34 | Potential: 53
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 53 Potential: 53
Field Value
LMK KEY 0753-2823-7860-9103-6575
ADDRESS1 60, Edinburgh Road
ADDRESS2
ADDRESS3
POSTCODE CW12 3EN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 37
POTENTIAL ENERGY EFFICIENCY 60
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-06-07
LOCAL AUTHORITY E06000049
CONSTITUENCY E14001178
COUNTY
LODGEMENT DATE 2017-06-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 53
ENERGY CONSUMPTION CURRENT 412
ENERGY CONSUMPTION POTENTIAL 242
CO2 EMISSIONS CURRENT 7.4
CO2 EMISS CURR PER FLOOR AREA 82
CO2 EMISSIONS POTENTIAL 4.5
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 1460
HEATING COST POTENTIAL 1097
HOT WATER COST CURRENT 103
HOT WATER COST POTENTIAL 58
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 10
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood), Room heaters, mains gas
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 60, Edinburgh Road
LOCAL AUTHORITY LABEL Cheshire East
CONSTITUENCY LABEL Congleton
POSTTOWN CONGLETON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2017-06-07 17:21:33
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100010040171
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000002
Address display
Nation ew