Energy Performance Certificate

33, Glenhurst Road, N12 9UB

EPC Report

Energy rating

Current: 55 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 47 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 70 Potential: 70
Field Value
LMK KEY 0747-2869-7881-9496-9155
ADDRESS1 33, Glenhurst Road
ADDRESS2
ADDRESS3
POSTCODE N12 9UB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Maisonette
BUILT FORM Semi-Detached
INSPECTION DATE 2016-08-11
LOCAL AUTHORITY E09000003
CONSTITUENCY E14001238
COUNTY
LODGEMENT DATE 2016-08-11
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 321
ENERGY CONSUMPTION POTENTIAL 173
CO2 EMISSIONS CURRENT 5.1
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 96
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 908
HEATING COST POTENTIAL 491
HOT WATER COST CURRENT 133
HOT WATER COST POTENTIAL 109
TOTAL FLOOR AREA 89
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH 0
FLOOR HEIGHT 2.54
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33, Glenhurst Road
LOCAL AUTHORITY LABEL Barnet
CONSTITUENCY LABEL Finchley and Golders Green
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-08-11 18:51:11
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 200047794
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000007
Address display
Nation ew