Energy Performance Certificate

19, St. Johns Chase, PE15 8RL

EPC Report

Energy rating

Current: 77 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 77 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 80 Potential: 80
Field Value
LMK KEY 0740-2870-7315-9993-4745
ADDRESS1 19, St. Johns Chase
ADDRESS2
ADDRESS3
POSTCODE PE15 8RL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-09-10
LOCAL AUTHORITY E07000010
CONSTITUENCY E14001390
COUNTY
LODGEMENT DATE 2017-09-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 145
ENERGY CONSUMPTION POTENTIAL 124
CO2 EMISSIONS CURRENT 2.1
CO2 EMISS CURR PER FLOOR AREA 25
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 331
HEATING COST POTENTIAL 337
HOT WATER COST CURRENT 105
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 84
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19, St. Johns Chase
LOCAL AUTHORITY LABEL Fenland
CONSTITUENCY LABEL North East Cambridgeshire
POSTTOWN MARCH
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2017-09-12 07:14:27
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10090577738
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000006
Address display
Nation ew