Energy Performance Certificate

54 Burcote Road, B24 0RN

EPC Report

Energy rating

Current: 60 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 60 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 77 Potential: 77
Field Value
LMK KEY 0739-7421-2000-0203-9202
ADDRESS1 54 Burcote Road
ADDRESS2
ADDRESS3
POSTCODE B24 0RN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2021-09-07
LOCAL AUTHORITY E08000025
CONSTITUENCY E14001093
COUNTY
LODGEMENT DATE 2021-09-08
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 60
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 259
ENERGY CONSUMPTION POTENTIAL 143
CO2 EMISSIONS CURRENT 3.7
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 111
LIGHTING COST POTENTIAL 72
HEATING COST CURRENT 753
HEATING COST POTENTIAL 710
HOT WATER COST CURRENT 132
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 81
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 45
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 45% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, supply and extract
ADDRESS 54 Burcote Road
LOCAL AUTHORITY LABEL Birmingham
CONSTITUENCY LABEL Birmingham Erdington
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2021-09-08 07:26:04
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100070312217
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000005
Address display
Nation ew