Energy Performance Certificate

62, Compton Road, CV6 6GQ

EPC Report

Energy rating

Current: 58 D | Potential: 98 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 98 A Potential: 98 A

Environmental impact (CO₂)

Current: 59 | Potential: 97
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 97 Potential: 97
Field Value
LMK KEY 0739-2862-7631-9905-8475
ADDRESS1 62, Compton Road
ADDRESS2
ADDRESS3
POSTCODE CV6 6GQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 98
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-07-02
LOCAL AUTHORITY E08000026
CONSTITUENCY E14001181
COUNTY
LODGEMENT DATE 2015-07-02
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 97
ENERGY CONSUMPTION CURRENT 263
ENERGY CONSUMPTION POTENTIAL 10
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 0.2
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 565
HEATING COST POTENTIAL 357
HOT WATER COST CURRENT 761
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 78
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 62, Compton Road
LOCAL AUTHORITY LABEL Coventry
CONSTITUENCY LABEL Coventry North West
POSTTOWN COVENTRY
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2015-07-02 09:47:33
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100070635406
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000005
Address display
Nation ew