Energy Performance Certificate

38, Hillcrest, Northside, CA14 1AG

EPC Report

Energy rating

Current: 59 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 52 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 78 Potential: 78
Field Value
LMK KEY 0738-9062-7221-3605-6980
ADDRESS1 38, Hillcrest
ADDRESS2 Northside
ADDRESS3
POSTCODE CA14 1AG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-09-07
LOCAL AUTHORITY E06000063
CONSTITUENCY E14001583
COUNTY
LODGEMENT DATE 2015-09-17
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 312
ENERGY CONSUMPTION POTENTIAL 135
CO2 EMISSIONS CURRENT 5.2
CO2 EMISS CURR PER FLOOR AREA 55
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 875
HEATING COST POTENTIAL 632
HOT WATER COST CURRENT 200
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 95
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 45
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 45% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 38, Hillcrest, Northside
LOCAL AUTHORITY LABEL Cumberland
CONSTITUENCY LABEL Whitehaven and Workington
POSTTOWN WORKINGTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-09-17 14:23:45
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10000880891
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000002
Address display
Nation ew