Energy Performance Certificate

4 Blacksmiths Yard, Main Street, Swanland, HU14 3QP

EPC Report

Energy rating

Current: 64 D | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 63 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 85 Potential: 85
Field Value
LMK KEY 0738-2001-7248-0802-8980
ADDRESS1 4 Blacksmiths Yard
ADDRESS2 Main Street
ADDRESS3 Swanland
POSTCODE HU14 3QP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2012-08-07
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001250
COUNTY
LODGEMENT DATE 2012-08-08
TRANSACTION TYPE rental (private)
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 261
ENERGY CONSUMPTION POTENTIAL 101
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 50
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 37
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 463
HEATING COST POTENTIAL 401
HOT WATER COST CURRENT 117
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 56
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4 Blacksmiths Yard, Main Street, Swanland
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Goole and Pocklington
POSTTOWN NORTH FERRIBY
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2012-08-08 15:14:53
TENURE
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 200000645693
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000003
Address display
Nation ew