Energy Performance Certificate

22 Alma Chase, Terrington St. Clement, PE34 4LJ

EPC Report

Energy rating

Current: 75 C | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 59 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 60 Potential: 60
Field Value
LMK KEY 0735-6729-7400-0602-3222
ADDRESS1 22 Alma Chase
ADDRESS2 Terrington St. Clement
ADDRESS3
POSTCODE PE34 4LJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2025-01-22
LOCAL AUTHORITY E07000146
CONSTITUENCY E14001405
COUNTY
LODGEMENT DATE 2025-01-22
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 373
ENERGY CONSUMPTION POTENTIAL 362
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 53
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 406
HEATING COST POTENTIAL 416
HOT WATER COST CURRENT 245
HOT WATER COST POTENTIAL 214
TOTAL FLOOR AREA 40
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 6.25
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22 Alma Chase, Terrington St. Clement
LOCAL AUTHORITY LABEL King's Lynn and West Norfolk
CONSTITUENCY LABEL North West Norfolk
POSTTOWN KING'S LYNN
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2025-01-22 23:37:09
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100090966300
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display