Energy Performance Certificate

43, Cotmore Way, Chillington, TQ7 2HU

EPC Report

Energy rating

Current: 61 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 54 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 81 Potential: 81
Field Value
LMK KEY 0735-2831-7220-9005-6875
ADDRESS1 43, Cotmore Way
ADDRESS2 Chillington
ADDRESS3
POSTCODE TQ7 2HU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-02-09
LOCAL AUTHORITY E07000044
CONSTITUENCY E14001484
COUNTY
LODGEMENT DATE 2015-02-09
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 176
ENERGY CONSUMPTION POTENTIAL 38
CO2 EMISSIONS CURRENT 4.0
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 557
HEATING COST POTENTIAL 342
HOT WATER COST CURRENT 195
HOT WATER COST POTENTIAL 97
TOTAL FLOOR AREA 88
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 43, Cotmore Way, Chillington
LOCAL AUTHORITY LABEL South Hams
CONSTITUENCY LABEL South Devon
POSTTOWN KINGSBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2015-02-09 17:01:51
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100040284483
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew