Energy Performance Certificate

20, Collingham, Orton Goldhay, PE2 5TN

EPC Report

Energy rating

Current: 49 E | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 42 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 73 Potential: 73
Field Value
LMK KEY 0731-2884-7089-9105-7735
ADDRESS1 20, Collingham
ADDRESS2 Orton Goldhay
ADDRESS3
POSTCODE PE2 5TN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2015-08-04
LOCAL AUTHORITY E06000031
CONSTITUENCY E14001401
COUNTY
LODGEMENT DATE 2015-08-07
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 410
ENERGY CONSUMPTION POTENTIAL 178
CO2 EMISSIONS CURRENT 5.2
CO2 EMISS CURR PER FLOOR AREA 72
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 50
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 802
HEATING COST POTENTIAL 402
HOT WATER COST CURRENT 296
HOT WATER COST POTENTIAL 116
TOTAL FLOOR AREA 72
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 20, Collingham, Orton Goldhay
LOCAL AUTHORITY LABEL Peterborough
CONSTITUENCY LABEL North West Cambridgeshire
POSTTOWN PETERBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2015-08-07 14:16:27
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100090185381
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew