Energy Performance Certificate

29, Strines Road, Marple, SK6 7DT

EPC Report

Energy rating

Current: 40 E | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 27 | Potential: 53
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 53 Potential: 53
Field Value
LMK KEY 0729-2805-7873-9504-2225
ADDRESS1 29, Strines Road
ADDRESS2 Marple
ADDRESS3
POSTCODE SK6 7DT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-03-05
LOCAL AUTHORITY E08000007
CONSTITUENCY E14001277
COUNTY
LODGEMENT DATE 2014-03-05
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 53
ENERGY CONSUMPTION CURRENT 334
ENERGY CONSUMPTION POTENTIAL 209
CO2 EMISSIONS CURRENT 23
CO2 EMISS CURR PER FLOOR AREA 73
CO2 EMISSIONS POTENTIAL 12
LIGHTING COST CURRENT 164
LIGHTING COST POTENTIAL 121
HEATING COST CURRENT 3941
HEATING COST POTENTIAL 2065
HOT WATER COST CURRENT 270
HOT WATER COST POTENTIAL 123
TOTAL FLOOR AREA 310
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 50
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 12
NUMBER HEATED ROOMS 11
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil, Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 29, Strines Road, Marple
LOCAL AUTHORITY LABEL Stockport
CONSTITUENCY LABEL Hazel Grove
POSTTOWN STOCKPORT
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2014-03-05 16:31:40
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 21
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 100011524130
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display
Nation ew