Energy Performance Certificate

2, Primrose Drive, Hartley Wintney, RG27 8TN

EPC Report

Energy rating

Current: 57 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 48 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 77 Potential: 77
Field Value
LMK KEY 0728-5044-7296-4556-1970
ADDRESS1 2, Primrose Drive
ADDRESS2 Hartley Wintney
ADDRESS3
POSTCODE RG27 8TN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-06-02
LOCAL AUTHORITY E07000089
CONSTITUENCY E14001392
COUNTY
LODGEMENT DATE 2016-06-03
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 270
ENERGY CONSUMPTION POTENTIAL 109
CO2 EMISSIONS CURRENT 7.9
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 155
LIGHTING COST POTENTIAL 85
HEATING COST CURRENT 1368
HEATING COST POTENTIAL 803
HOT WATER COST CURRENT 199
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 165
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Primrose Drive, Hartley Wintney
LOCAL AUTHORITY LABEL Hart
CONSTITUENCY LABEL North East Hampshire
POSTTOWN HOOK
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2016-06-03 21:16:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100060421976
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000008
Address display
Nation ew