Energy Performance Certificate

Mount House, Main Road, Nawton, YO62 7RD

EPC Report

Energy rating

Current: 45 E | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 18 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 Current: 18 88 Potential: 88
Field Value
LMK KEY 0721-2841-7461-9204-7941
ADDRESS1 Mount House
ADDRESS2 Main Road
ADDRESS3 Nawton
POSTCODE YO62 7RD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2014-06-09
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001544
COUNTY
LODGEMENT DATE 2014-06-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 18
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 424
ENERGY CONSUMPTION POTENTIAL 74
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 122
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 1254
HEATING COST POTENTIAL 453
HOT WATER COST CURRENT 229
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 99
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 50
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, coal
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL house coal (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Mount House, Main Road, Nawton
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Thirsk and Malton
POSTTOWN YORK
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-06-10 20:17:19
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100050456853
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000003
Address display
Nation ew