Energy Performance Certificate

16, Hedley Street, TS14 6EG

EPC Report

Energy rating

Current: 1 G | Potential: 44 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 44 E Potential: 44 E

Environmental impact (CO₂)

Current: 19 | Potential: 59
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 19 Current: 19 59 Potential: 59
Field Value
LMK KEY 0718-7034-7233-4308-8900
ADDRESS1 16, Hedley Street
ADDRESS2
ADDRESS3
POSTCODE TS14 6EG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 44
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-07-09
LOCAL AUTHORITY E06000003
CONSTITUENCY E14001368
COUNTY
LODGEMENT DATE 2018-07-09
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 19
ENVIRONMENT IMPACT POTENTIAL 59
ENERGY CONSUMPTION CURRENT 841
ENERGY CONSUMPTION POTENTIAL 358
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 121
CO2 EMISSIONS POTENTIAL 5.3
LIGHTING COST CURRENT 143
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 3777
HEATING COST POTENTIAL 2047
HOT WATER COST CURRENT 861
HOT WATER COST POTENTIAL 192
TOTAL FLOOR AREA 109
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL wood logs
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.63
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16, Hedley Street
LOCAL AUTHORITY LABEL Redcar and Cleveland
CONSTITUENCY LABEL Middlesbrough South and East Cleveland
POSTTOWN GUISBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2018-07-09 14:50:46
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100110038989
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000001
Address display
Nation ew