Energy Performance Certificate

31, Longbeach Road, SW11 5SS

EPC Report

Energy rating

Current: 59 D | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 53 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 71 Potential: 71
Field Value
LMK KEY 0717-2834-7613-9307-3995
ADDRESS1 31, Longbeach Road
ADDRESS2
ADDRESS3
POSTCODE SW11 5SS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-09-04
LOCAL AUTHORITY E09000032
CONSTITUENCY E14001081
COUNTY
LODGEMENT DATE 2013-09-05
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 220
ENERGY CONSUMPTION POTENTIAL 127
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 4.2
LIGHTING COST CURRENT 146
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 1203
HEATING COST POTENTIAL 936
HOT WATER COST CURRENT 124
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 168
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 54
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 5
NUMBER OPEN FIREPLACES 4
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 5% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31, Longbeach Road
LOCAL AUTHORITY LABEL Wandsworth
CONSTITUENCY LABEL Battersea
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-09-05 17:26:10
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100022664969
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000007
Address display
Nation ew