Energy Performance Certificate

65, Goldfinch Road, CR2 8SR

EPC Report

Energy rating

Current: 62 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 59 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 79 Potential: 79
Field Value
LMK KEY 0716-2808-7361-9627-1085
ADDRESS1 65, Goldfinch Road
ADDRESS2
ADDRESS3
POSTCODE CR2 8SR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2013-06-28
LOCAL AUTHORITY E09000008
CONSTITUENCY E14001186
COUNTY
LODGEMENT DATE 2013-06-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 226
ENERGY CONSUMPTION POTENTIAL 109
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 85
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 631
HEATING COST POTENTIAL 525
HOT WATER COST CURRENT 98
HOT WATER COST POTENTIAL 66
TOTAL FLOOR AREA 87
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 91
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 24
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), ceiling insulated
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 24% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 65, Goldfinch Road
LOCAL AUTHORITY LABEL Croydon
CONSTITUENCY LABEL Croydon East
POSTTOWN SOUTH CROYDON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2013-06-28 14:28:06
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100020678415
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000007
Address display
Nation ew