Energy Performance Certificate

7a Halton Way, Credenhill, HR4 7EB

EPC Report

Energy rating

Current: 78 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 80 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 Current: 80 80 Potential: 80
Field Value
LMK KEY 0715-3825-7481-9597-7715
ADDRESS1 7a Halton Way
ADDRESS2 Credenhill
ADDRESS3
POSTCODE HR4 7EB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-08-15
LOCAL AUTHORITY E06000019
CONSTITUENCY E14001395
COUNTY
LODGEMENT DATE 2013-08-15
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 80
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 124
ENERGY CONSUMPTION POTENTIAL 124
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 24
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 350
HEATING COST POTENTIAL 350
HOT WATER COST CURRENT 91
HOT WATER COST POTENTIAL 91
TOTAL FLOOR AREA 82
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 76
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.17 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.24 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.13 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 76% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 7a Halton Way, Credenhill
LOCAL AUTHORITY LABEL Herefordshire, County of
CONSTITUENCY LABEL North Herefordshire
POSTTOWN HEREFORD
CONSTRUCTION AGE BAND 2010
LODGEMENT DATETIME 2013-08-15 20:28:05
TENURE
FIXED LIGHTING OUTLETS COUNT 21
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 10023977571