Energy Performance Certificate

Horseshoe Cottage, Sennen, TR19 7AD

EPC Report

Energy rating

Current: 31 F | Potential: 97 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 F Current: 31 F 97 A Potential: 97 A

Environmental impact (CO₂)

Current: 18 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 Current: 18 70 Potential: 70
Field Value
LMK KEY 0712-2863-7875-9425-4571
ADDRESS1 Horseshoe Cottage
ADDRESS2 Sennen
ADDRESS3
POSTCODE TR19 7AD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 31
POTENTIAL ENERGY EFFICIENCY 97
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-03-27
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001511
COUNTY
LODGEMENT DATE 2015-03-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 18
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 648
ENERGY CONSUMPTION POTENTIAL 164
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 110
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 69
LIGHTING COST POTENTIAL 70
HEATING COST CURRENT 1434
HEATING COST POTENTIAL 723
HOT WATER COST CURRENT 383
HOT WATER COST POTENTIAL 93
TOTAL FLOOR AREA 99
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 30
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 94
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 94% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.63
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Horseshoe Cottage, Sennen
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL St Ives
POSTTOWN PENZANCE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-03-27 18:04:41
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 17
UPRN 10014483790
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display