Energy Performance Certificate

9, Sevenacres, Orton Brimbles, PE2 5XH

EPC Report

Energy rating

Current: 59 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 59 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 82 Potential: 82
Field Value
LMK KEY 0707-2853-7422-9427-7111
ADDRESS1 9, Sevenacres
ADDRESS2 Orton Brimbles
ADDRESS3
POSTCODE PE2 5XH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-02-27
LOCAL AUTHORITY E06000031
CONSTITUENCY E14001401
COUNTY
LODGEMENT DATE 2013-02-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 238
ENERGY CONSUMPTION POTENTIAL 98
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 591
HEATING COST POTENTIAL 455
HOT WATER COST CURRENT 272
HOT WATER COST POTENTIAL 157
TOTAL FLOOR AREA 91
ENERGY TARIFF Unknown
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9, Sevenacres, Orton Brimbles
LOCAL AUTHORITY LABEL Peterborough
CONSTITUENCY LABEL North West Cambridgeshire
POSTTOWN PETERBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2013-02-27 14:13:12
TENURE Unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100090219411
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000006
Address display
Nation ew