Energy Performance Certificate

4 Burnsall Court, LS12 3NX

EPC Report

Energy rating

Current: 35 F | Potential: 36 F
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 36 F Potential: 36 F

Environmental impact (CO₂)

Current: 19 | Potential: 19
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 19 Current: 19 19 Potential: 19
Field Value
LMK KEY 0699-0022-3379-4917-1204
ADDRESS1 4 Burnsall Court
ADDRESS2
ADDRESS3
POSTCODE LS12 3NX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING F
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 36
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2023-01-01
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001325
COUNTY
LODGEMENT DATE 2023-01-25
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 19
ENVIRONMENT IMPACT POTENTIAL 19
ENERGY CONSUMPTION CURRENT 906
ENERGY CONSUMPTION POTENTIAL 903
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 153
CO2 EMISSIONS POTENTIAL 7.6
LIGHTING COST CURRENT 82
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 1522
HEATING COST POTENTIAL 1529
HOT WATER COST CURRENT 415
HOT WATER COST POTENTIAL 415
TOTAL FLOOR AREA 50
ENERGY TARIFF off-peak 7 hour
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Average thermal transmittance 1.20 W/m²K
FLOOR ENERGY EFF Very Poor
FLOOR ENV EFF Very Poor
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Average thermal transmittance 1.58 W/m²K
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters, radiators
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 4 Burnsall Court
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds West and Pudsey
POSTTOWN LEEDS
CONSTRUCTION AGE BAND 1963
LODGEMENT DATETIME 2023-01-25 13:17:49
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 72211439
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2023.csv
COUNTRY England
REGION E12000003
Address display
Nation ew