Energy Performance Certificate

1, Bridge Terrace, Upper Hulme, ST13 8TU

EPC Report

Energy rating

Current: 25 F | Potential: 64 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 F Current: 25 F 64 D Potential: 64 D

Environmental impact (CO₂)

Current: 53 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 82 Potential: 82
Field Value
LMK KEY 0695-2883-6571-2590-5445
ADDRESS1 1, Bridge Terrace
ADDRESS2 Upper Hulme
ADDRESS3
POSTCODE ST13 8TU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 25
POTENTIAL ENERGY EFFICIENCY 64
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2020-03-17
LOCAL AUTHORITY E07000198
CONSTITUENCY E14001514
COUNTY
LODGEMENT DATE 2020-03-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 281
ENERGY CONSUMPTION POTENTIAL 95
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 61
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 56
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 1459
HEATING COST POTENTIAL 856
HOT WATER COST CURRENT 247
HOT WATER COST POTENTIAL 134
TOTAL FLOOR AREA 69
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL bottled LPG
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.89
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Bridge Terrace, Upper Hulme
LOCAL AUTHORITY LABEL Staffordshire Moorlands
CONSTITUENCY LABEL Staffordshire Moorlands
POSTTOWN LEEK
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2020-03-19 08:55:50
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 200001572498
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000005
Address display
Nation ew