Energy Performance Certificate

5, Rivington Road, PR6 0EX

EPC Report

Energy rating

Current: 60 D | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 58 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 86 Potential: 86
Field Value
LMK KEY 0688-4946-7269-0457-2990
ADDRESS1 5, Rivington Road
ADDRESS2
ADDRESS3
POSTCODE PR6 0EX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-11-08
LOCAL AUTHORITY E07000118
CONSTITUENCY E14001170
COUNTY
LODGEMENT DATE 2013-11-08
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 279
ENERGY CONSUMPTION POTENTIAL 91
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 589
HEATING COST POTENTIAL 425
HOT WATER COST CURRENT 79
HOT WATER COST POTENTIAL 56
TOTAL FLOOR AREA 60
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazeddouble glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Rivington Road
LOCAL AUTHORITY LABEL Chorley
CONSTITUENCY LABEL Chorley
POSTTOWN CHORLEY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2013-11-08 15:03:03
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100010383750
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display