Energy Performance Certificate

33, The Highway, New Inn, NP4 0PW

EPC Report

Energy rating

Current: 40 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 34 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 75 Potential: 75
Field Value
LMK KEY 0688-0084-7225-1985-7990
ADDRESS1 33, The Highway
ADDRESS2 New Inn
ADDRESS3
POSTCODE NP4 0PW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-05-08
LOCAL AUTHORITY W06000020
CONSTITUENCY W07000109
COUNTY
LODGEMENT DATE 2015-05-26
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 443
ENERGY CONSUMPTION POTENTIAL 149
CO2 EMISSIONS CURRENT 11.0
CO2 EMISS CURR PER FLOOR AREA 78
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 102
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 1918
HEATING COST POTENTIAL 948
HOT WATER COST CURRENT 315
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 138
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 61
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 61% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.66
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33, The Highway, New Inn
LOCAL AUTHORITY LABEL Torfaen
CONSTITUENCY LABEL Torfaen
POSTTOWN PONTYPOOL
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-05-26 20:24:37
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100100978663
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew