Energy Performance Certificate

76 Bristol Avenue, Farington, PR25 4GD

EPC Report

Energy rating

Current: 38 F | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 32 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 82 Potential: 82
Field Value
LMK KEY 0677-3922-5200-3882-4200
ADDRESS1 76 Bristol Avenue
ADDRESS2 Farington
ADDRESS3
POSTCODE PR25 4GD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2022-10-03
LOCAL AUTHORITY E07000126
CONSTITUENCY E14001491
COUNTY
LODGEMENT DATE 2022-12-02
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 512
ENERGY CONSUMPTION POTENTIAL 114
CO2 EMISSIONS CURRENT 6.6
CO2 EMISS CURR PER FLOOR AREA 90
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 533
HEATING COST POTENTIAL 431
HOT WATER COST CURRENT 678
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 73
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 76 Bristol Avenue, Farington
LOCAL AUTHORITY LABEL South Ribble
CONSTITUENCY LABEL South Ribble
POSTTOWN LEYLAND
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2022-12-02 17:59:33
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100010621863
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000002
Address display
Nation ew