Energy Performance Certificate
Flat 53, Whistler Tower, World's End Estate, SW10 0ED
Energy rating
Current: 67 D | Potential: 74 C
Environmental impact (CO₂)
Current: 64
| Potential: 74
| Field | Value |
|---|---|
| LMK KEY | 0675-3050-1205-4635-2200 |
| ADDRESS1 | Flat 53 |
| ADDRESS2 | Whistler Tower |
| ADDRESS3 | World's End Estate |
| POSTCODE | SW10 0ED |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 67 |
| POTENTIAL ENERGY EFFICIENCY | 74 |
| PROPERTY TYPE | Flat |
| BUILT FORM | Not Recorded |
| INSPECTION DATE | 2025-05-03 |
| LOCAL AUTHORITY | E09000020 |
| CONSTITUENCY | E14001160 |
| COUNTY | — |
| LODGEMENT DATE | 2026-02-15 |
| TRANSACTION TYPE | None of the above |
| ENVIRONMENT IMPACT CURRENT | 64 |
| ENVIRONMENT IMPACT POTENTIAL | 74 |
| ENERGY CONSUMPTION CURRENT | 201 |
| ENERGY CONSUMPTION POTENTIAL | 146 |
| CO2 EMISSIONS CURRENT | 2.8 |
| CO2 EMISS CURR PER FLOOR AREA | 37 |
| CO2 EMISSIONS POTENTIAL | 2.0 |
| LIGHTING COST CURRENT | 58 |
| LIGHTING COST POTENTIAL | 58 |
| HEATING COST CURRENT | 535 |
| HEATING COST POTENTIAL | 346 |
| HOT WATER COST CURRENT | 246 |
| HOT WATER COST POTENTIAL | 246 |
| TOTAL FLOOR AREA | 75 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | 2 |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Flat rate charging, no thermostatic control of room temperature |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 3 |
| NUMBER HEATED ROOMS | 3 |
| LOW ENERGY LIGHTING | 90 |
| NUMBER OPEN FIREPLACES | — |
| HOTWATER DESCRIPTION | Community scheme |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Average |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Poor |
| WINDOWS ENV EFF | Poor |
| WALLS DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Poor |
| WALLS ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| MAINHEAT DESCRIPTION | Community scheme |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Average |
| MAINHEATCONT DESCRIPTION | Flat rate charging, no thermostatic control of room temperature |
| MAINHEATC ENERGY EFF | Very Poor |
| MAINHEATC ENV EFF | Very Poor |
| LIGHTING DESCRIPTION | Below average lighting efficiency |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| MAIN FUEL | mains gas (community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | no corridor |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.3 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | Flat 53, Whistler Tower, World's End Estate |
| LOCAL AUTHORITY LABEL | Kensington and Chelsea |
| CONSTITUENCY LABEL | Chelsea and Fulham |
| POSTTOWN | LONDON |
| CONSTRUCTION AGE BAND | England and Wales: 1967-1975 |
| LODGEMENT DATETIME | 2026-02-15 00:50:12 |
| TENURE | rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 9 |
| UPRN | 217093516 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2026.csv |
| COUNTRY | England |
| REGION | E12000007 |
| Address display | — |
| Nation | ew |