Energy Performance Certificate

28, Boundary Road, CA2 4HH

EPC Report

Energy rating

Current: 56 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 49 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 66 Potential: 66
Field Value
LMK KEY 0673-2802-6362-9306-9761
ADDRESS1 28, Boundary Road
ADDRESS2
ADDRESS3
POSTCODE CA2 4HH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-06-02
LOCAL AUTHORITY E06000063
CONSTITUENCY E14001152
COUNTY
LODGEMENT DATE 2016-06-02
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 323
ENERGY CONSUMPTION POTENTIAL 208
CO2 EMISSIONS CURRENT 5.6
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 117
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 1023
HEATING COST POTENTIAL 887
HOT WATER COST CURRENT 115
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 98
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 83
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 10
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 10% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.02
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 28, Boundary Road
LOCAL AUTHORITY LABEL Cumberland
CONSTITUENCY LABEL Carlisle
POSTTOWN CARLISLE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-06-02 18:53:01
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100110272906
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display
Nation ew