Energy Performance Certificate

Flat 5, 36 Selborne Road, BN3 3AH

EPC Report

Energy rating

Current: 42 E | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 48 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 68 Potential: 68
Field Value
LMK KEY 0672-2834-6322-2490-2451
ADDRESS1 Flat 5
ADDRESS2 36 Selborne Road
ADDRESS3
POSTCODE BN3 3AH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Flat
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2020-02-14
LOCAL AUTHORITY E06000043
CONSTITUENCY E14001296
COUNTY
LODGEMENT DATE 2020-02-14
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 536
ENERGY CONSUMPTION POTENTIAL 326
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 91
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 35
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 643
HEATING COST POTENTIAL 146
HOT WATER COST CURRENT 297
HOT WATER COST POTENTIAL 139
TOTAL FLOOR AREA 31
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 75
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 7.72
FLOOR HEIGHT 2.98
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 5, 36 Selborne Road
LOCAL AUTHORITY LABEL Brighton and Hove
CONSTITUENCY LABEL Hove and Portslade
POSTTOWN HOVE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2020-02-14 13:19:53
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 22141187
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew