Energy Performance Certificate

57 LIME TREE WALK, NEWTON ABBOT, TQ12 4LF

EPC Report

Energy rating

Current: 57 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 49 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 76 Potential: 76
Field Value
LMK KEY 0656-3901-6209-5520-2200
ADDRESS1 57 LIME TREE WALK
ADDRESS2 NEWTON ABBOT
ADDRESS3
POSTCODE TQ12 4LF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2020-11-05
LOCAL AUTHORITY E07000045
CONSTITUENCY E14001381
COUNTY
LODGEMENT DATE 2020-11-05
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 278
ENERGY CONSUMPTION POTENTIAL 107
CO2 EMISSIONS CURRENT 4.5
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 701
HEATING COST POTENTIAL 508
HOT WATER COST CURRENT 193
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 92
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 91
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 91% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 57 LIME TREE WALK, NEWTON ABBOT
LOCAL AUTHORITY LABEL Teignbridge
CONSTITUENCY LABEL Newton Abbot
POSTTOWN NEWTON ABBOT
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2020-11-05 13:22:42
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100040325995
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000009
Address display
Nation ew