Energy Performance Certificate

31, Longhurst Close, LE4 7WA

EPC Report

Energy rating

Current: 52 E | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 54 | Potential: 99
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 99 Potential: 99
Field Value
LMK KEY 0654-2862-6356-9522-5065
ADDRESS1 31, Longhurst Close
ADDRESS2
ADDRESS3
POSTCODE LE4 7WA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2012-05-22
LOCAL AUTHORITY E06000016
CONSTITUENCY E14001326
COUNTY
LODGEMENT DATE 2012-05-23
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 99
ENERGY CONSUMPTION CURRENT 387
ENERGY CONSUMPTION POTENTIAL 1
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 73
CO2 EMISSIONS POTENTIAL 0.1
LIGHTING COST CURRENT 30
LIGHTING COST POTENTIAL 30
HEATING COST CURRENT 449
HEATING COST POTENTIAL 226
HOT WATER COST CURRENT 180
HOT WATER COST POTENTIAL 57
TOTAL FLOOR AREA 38
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.335
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31, Longhurst Close
LOCAL AUTHORITY LABEL Leicester
CONSTITUENCY LABEL Leicester East
POSTTOWN LEICESTER
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2012-05-23 17:29:11
TENURE
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 2465124800
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000004
Address display
Nation ew