Energy Performance Certificate

14, Windsor Road, Pattingham, WV6 7DR

EPC Report

Energy rating

Current: 70 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 66 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 77 Potential: 77
Field Value
LMK KEY 0651-2803-7775-9403-5601
ADDRESS1 14, Windsor Road
ADDRESS2 Pattingham
ADDRESS3
POSTCODE WV6 7DR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2017-03-07
LOCAL AUTHORITY E07000196
CONSTITUENCY E14001316
COUNTY
LODGEMENT DATE 2017-03-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 66
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 196
ENERGY CONSUMPTION POTENTIAL 127
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 35
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 116
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 709
HEATING COST POTENTIAL 646
HOT WATER COST CURRENT 115
HOT WATER COST POTENTIAL 115
TOTAL FLOOR AREA 119
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 37
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 37% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14, Windsor Road, Pattingham
LOCAL AUTHORITY LABEL South Staffordshire
CONSTITUENCY LABEL Kingswinford and South Staffordshire
POSTTOWN WOLVERHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2017-03-07 20:25:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100031833294
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000005
Address display
Nation ew