Energy Performance Certificate

Stable Cottage, Rock, PL27 6LD

EPC Report

Energy rating

Current: 38 F | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 33 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 63 Potential: 63
Field Value
LMK KEY 0648-2012-7256-6341-9920
ADDRESS1 Stable Cottage
ADDRESS2 Rock
ADDRESS3
POSTCODE PL27 6LD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-06-04
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001385
COUNTY
LODGEMENT DATE 2019-06-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 252
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 65
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 141
LIGHTING COST POTENTIAL 90
HEATING COST CURRENT 1263
HEATING COST POTENTIAL 682
HOT WATER COST CURRENT 110
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 154
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 50
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 42
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 42% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS Stable Cottage, Rock
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL North Cornwall
POSTTOWN WADEBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2019-06-06 19:43:00
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10003293531
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000009
Address display
Nation ew