Energy Performance Certificate

Holme View, 53 Esk Street, Longtown, CA6 5PU

EPC Report

Energy rating

Current: 17 G | Potential: 61 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 G Current: 17 G 61 D Potential: 61 D

Environmental impact (CO₂)

Current: 10 | Potential: 45
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 10 Current: 10 45 Potential: 45
Field Value
LMK KEY 0645-2857-7436-9996-7901
ADDRESS1 Holme View
ADDRESS2 53 Esk Street
ADDRESS3 Longtown
POSTCODE CA6 5PU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 17
POTENTIAL ENERGY EFFICIENCY 61
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2016-07-13
LOCAL AUTHORITY E06000063
CONSTITUENCY E14001152
COUNTY
LODGEMENT DATE 2016-07-13
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 10
ENVIRONMENT IMPACT POTENTIAL 45
ENERGY CONSUMPTION CURRENT 504
ENERGY CONSUMPTION POTENTIAL 208
CO2 EMISSIONS CURRENT 26
CO2 EMISS CURR PER FLOOR AREA 123
CO2 EMISSIONS POTENTIAL 11
LIGHTING COST CURRENT 109
LIGHTING COST POTENTIAL 109
HEATING COST CURRENT 4339
HEATING COST POTENTIAL 1933
HOT WATER COST CURRENT 289
HOT WATER COST POTENTIAL 152
TOTAL FLOOR AREA 215
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.04
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Holme View, 53 Esk Street, Longtown
LOCAL AUTHORITY LABEL Cumberland
CONSTITUENCY LABEL Carlisle
POSTTOWN CARLISLE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-07-13 19:11:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100110737285
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display