Energy Performance Certificate

1, Condor Close, SO19 9TH

EPC Report

Energy rating

Current: 47 E | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 29 | Potential: 58
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 Current: 29 58 Potential: 58
Field Value
LMK KEY 0642-2886-7653-2820-9565
ADDRESS1 1, Condor Close
ADDRESS2
ADDRESS3
POSTCODE SO19 9TH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2020-05-26
LOCAL AUTHORITY E06000045
CONSTITUENCY E14001499
COUNTY
LODGEMENT DATE 2020-05-28
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 29
ENVIRONMENT IMPACT POTENTIAL 58
ENERGY CONSUMPTION CURRENT 627
ENERGY CONSUMPTION POTENTIAL 308
CO2 EMISSIONS CURRENT 5.1
CO2 EMISS CURR PER FLOOR AREA 106
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 65
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 801
HEATING COST POTENTIAL 297
HOT WATER COST CURRENT 183
HOT WATER COST POTENTIAL 161
TOTAL FLOOR AREA 48
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 63% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 2.1
FLOOR HEIGHT 2.55
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Condor Close
LOCAL AUTHORITY LABEL Southampton
CONSTITUENCY LABEL Southampton Itchen
POSTTOWN SOUTHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2020-05-28 16:48:37
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10034862699
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew