Energy Performance Certificate

13 Throstle Close, Langthorpe, YO51 9PN

EPC Report

Energy rating

Current: 84 B | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 B Current: 84 B 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 84 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 Current: 84 90 Potential: 90
Field Value
LMK KEY 0641-3520-4341-2722-9155
ADDRESS1 13 Throstle Close
ADDRESS2 Langthorpe
ADDRESS3
POSTCODE YO51 9PN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 84
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-04-20
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001582
COUNTY
LODGEMENT DATE 2022-04-20
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 84
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 89
ENERGY CONSUMPTION POTENTIAL 55
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 16
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 103
LIGHTING COST POTENTIAL 103
HEATING COST CURRENT 389
HEATING COST POTENTIAL 389
HOT WATER COST CURRENT 71
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 153
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.14 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.27 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.09 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.815
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 13 Throstle Close, Langthorpe
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Wetherby and Easingwold
POSTTOWN BOROUGHBRIDGE
CONSTRUCTION AGE BAND 2022
LODGEMENT DATETIME 2022-04-20 12:57:39
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 1
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 10094452031
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2022.csv
COUNTRY England
REGION E12000003
Address display
Nation ew