Energy Performance Certificate

20b, Duke Street, Arnold, NG5 6GQ

EPC Report

Energy rating

Current: 54 E | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 51 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 91 Potential: 91
Field Value
LMK KEY 0639-2846-7173-9195-8965
ADDRESS1 20b, Duke Street
ADDRESS2 Arnold
ADDRESS3
POSTCODE NG5 6GQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-03-16
LOCAL AUTHORITY E07000173
CONSTITUENCY E14001245
COUNTY
LODGEMENT DATE 2015-03-16
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 377
ENERGY CONSUMPTION POTENTIAL 60
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 50
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 585
HEATING COST POTENTIAL 336
HOT WATER COST CURRENT 229
HOT WATER COST POTENTIAL 66
TOTAL FLOOR AREA 55
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 20b, Duke Street, Arnold
LOCAL AUTHORITY LABEL Gedling
CONSTITUENCY LABEL Gedling
POSTTOWN NOTTINGHAM
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2015-03-16 10:49:19
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100031357697
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew