Energy Performance Certificate

63, Oozehead Lane, BB2 6NH

EPC Report

Energy rating

Current: 10 G | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 10 G Current: 10 G 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 24 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 Current: 24 74 Potential: 74
Field Value
LMK KEY 0638-8024-7201-3855-5910
ADDRESS1 63, Oozehead Lane
ADDRESS2
ADDRESS3
POSTCODE BB2 6NH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 10
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-09-07
LOCAL AUTHORITY E06000008
CONSTITUENCY E14001102
COUNTY
LODGEMENT DATE 2015-09-07
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 24
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 603
ENERGY CONSUMPTION POTENTIAL 153
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 102
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 2611
HEATING COST POTENTIAL 711
HOT WATER COST CURRENT 398
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 104
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.77
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 63, Oozehead Lane
LOCAL AUTHORITY LABEL Blackburn with Darwen
CONSTITUENCY LABEL Blackburn
POSTTOWN BLACKBURN
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-09-07 15:15:51
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10