Energy Performance Certificate

26, Falstone, GU21 3HU

EPC Report

Energy rating

Current: 49 E | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 46 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 88 Potential: 88
Field Value
LMK KEY 0633-2892-7018-9325-6041
ADDRESS1 26, Falstone
ADDRESS2
ADDRESS3
POSTCODE GU21 3HU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-09-22
LOCAL AUTHORITY E07000217
CONSTITUENCY E14001592
COUNTY
LODGEMENT DATE 2015-09-24
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 389
ENERGY CONSUMPTION POTENTIAL 63
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 65
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 728
HEATING COST POTENTIAL 342
HOT WATER COST CURRENT 194
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 62
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 26, Falstone
LOCAL AUTHORITY LABEL Woking
CONSTITUENCY LABEL Woking
POSTTOWN WOKING
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2015-09-24 15:05:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100061643973
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew