Energy Performance Certificate

2 Tolmers Gardens, Cuffley, EN6 4JE

EPC Report

Energy rating

Current: 75 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 72 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 Current: 72 74 Potential: 74
Field Value
LMK KEY 0620-3058-9202-1176-6204
ADDRESS1 2 Tolmers Gardens
ADDRESS2 Cuffley
ADDRESS3
POSTCODE EN6 4JE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2026-02-02
LOCAL AUTHORITY E07000241
CONSTITUENCY E14001284
COUNTY
LODGEMENT DATE 2026-02-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 72
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 136
ENERGY CONSUMPTION POTENTIAL 120
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 25
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 94
HEATING COST CURRENT 1407
HEATING COST POTENTIAL 1300
HOT WATER COST CURRENT 252
HOT WATER COST POTENTIAL 252
TOTAL FLOOR AREA 197
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 Tolmers Gardens, Cuffley
LOCAL AUTHORITY LABEL Welwyn Hatfield
CONSTITUENCY LABEL Hertsmere
POSTTOWN POTTERS BAR
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2026-02-04 15:12:50
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 80
LOW ENERGY FIXED LIGHT COUNT 80
UPRN 100080970469
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000006
Address display
Nation ew