Energy Performance Certificate

19, Draper Crescent, RG40 1GW

EPC Report

Energy rating

Current: 89 B | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 89 B Current: 89 B 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 90 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 90 Current: 90 92 Potential: 92
Field Value
LMK KEY 0618-2973-7322-4686-9934
ADDRESS1 19, Draper Crescent
ADDRESS2
ADDRESS3
POSTCODE RG40 1GW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 89
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-12-09
LOCAL AUTHORITY E06000041
CONSTITUENCY E14001593
COUNTY
LODGEMENT DATE 2016-12-09
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 90
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 54
ENERGY CONSUMPTION POTENTIAL 40
CO2 EMISSIONS CURRENT 1.0
CO2 EMISS CURR PER FLOOR AREA 10
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 70
LIGHTING COST POTENTIAL 70
HEATING COST CURRENT 227
HEATING COST POTENTIAL 228
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 57
TOTAL FLOOR AREA 103
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.08 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.27 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.09 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 19, Draper Crescent
LOCAL AUTHORITY LABEL Wokingham
CONSTITUENCY LABEL Wokingham
POSTTOWN WOKINGHAM
CONSTRUCTION AGE BAND 2015
LODGEMENT DATETIME 2016-12-09 13:17:40
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 10032936789
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY England