Energy Performance Certificate

4, Clippers Quay, Merchants Landing, BB1 1EB

EPC Report

Energy rating

Current: 65 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 51 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 64 Potential: 64
Field Value
LMK KEY 0618-2899-7641-9294-6485
ADDRESS1 4, Clippers Quay
ADDRESS2 Merchants Landing
ADDRESS3
POSTCODE BB1 1EB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-04-11
LOCAL AUTHORITY E06000008
CONSTITUENCY E14001102
COUNTY
LODGEMENT DATE 2014-04-17
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 387
ENERGY CONSUMPTION POTENTIAL 283
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 68
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 64
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 364
HEATING COST POTENTIAL 210
HOT WATER COST CURRENT 181
HOT WATER COST POTENTIAL 112
TOTAL FLOOR AREA 49
ENERGY TARIFF Unknown
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH 3.8
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4, Clippers Quay, Merchants Landing
LOCAL AUTHORITY LABEL Blackburn with Darwen
CONSTITUENCY LABEL Blackburn
POSTTOWN BLACKBURN
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2014-04-17 20:41:42
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100012425169
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display
Nation ew