Energy Performance Certificate

Tangle Copse, Sherbourne Drive, SL5 0LG

EPC Report

Energy rating

Current: 26 F | Potential: 65 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 F Current: 26 F 65 D Potential: 65 D

Environmental impact (CO₂)

Current: 19 | Potential: 51
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 19 Current: 19 51 Potential: 51
Field Value
LMK KEY 0618-2834-7311-9897-1611
ADDRESS1 Tangle Copse
ADDRESS2 Sherbourne Drive
ADDRESS3
POSTCODE SL5 0LG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 26
POTENTIAL ENERGY EFFICIENCY 65
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-09-14
LOCAL AUTHORITY E07000212
CONSTITUENCY E14001588
COUNTY
LODGEMENT DATE 2013-09-14
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 19
ENVIRONMENT IMPACT POTENTIAL 51
ENERGY CONSUMPTION CURRENT 410
ENERGY CONSUMPTION POTENTIAL 182
CO2 EMISSIONS CURRENT 27
CO2 EMISS CURR PER FLOOR AREA 86
CO2 EMISSIONS POTENTIAL 12
LIGHTING COST CURRENT 204
LIGHTING COST POTENTIAL 107
HEATING COST CURRENT 4305
HEATING COST POTENTIAL 2180
HOT WATER COST CURRENT 257
HOT WATER COST POTENTIAL 151
TOTAL FLOOR AREA 313
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 5
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 12
NUMBER HEATED ROOMS 12
LOW ENERGY LIGHTING 5
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 5% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.54
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Tangle Copse, Sherbourne Drive
LOCAL AUTHORITY LABEL Runnymede
CONSTITUENCY LABEL Windsor
POSTTOWN ASCOT
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2013-09-14 15:41:14
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 63
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100061491424
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000008
Address display
Nation ew