Energy Performance Certificate

5, Chapel Rise, Worthington, LE65 1RX

EPC Report

Energy rating

Current: 36 F | Potential: 50 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 F Current: 36 F 50 E Potential: 50 E

Environmental impact (CO₂)

Current: 32 | Potential: 43
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 43 Potential: 43
Field Value
LMK KEY 0618-2821-7987-9407-4155
ADDRESS1 5, Chapel Rise
ADDRESS2 Worthington
ADDRESS3
POSTCODE LE65 1RX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 36
POTENTIAL ENERGY EFFICIENCY 50
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2013-08-09
LOCAL AUTHORITY E07000134
CONSTITUENCY E14001404
COUNTY
LODGEMENT DATE 2013-08-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 43
ENERGY CONSUMPTION CURRENT 458
ENERGY CONSUMPTION POTENTIAL 349
CO2 EMISSIONS CURRENT 8.5
CO2 EMISS CURR PER FLOOR AREA 81
CO2 EMISSIONS POTENTIAL 6.5
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 1592
HEATING COST POTENTIAL 1483
HOT WATER COST CURRENT 168
HOT WATER COST POTENTIAL 106
TOTAL FLOOR AREA 105
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Chapel Rise, Worthington
LOCAL AUTHORITY LABEL North West Leicestershire
CONSTITUENCY LABEL North West Leicestershire
POSTTOWN ASHBY-DE-LA-ZOUCH
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2013-08-09 15:31:47
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100030551506
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000004
Address display
Nation ew