Energy Performance Certificate

Flat 1, 92, Scalby Road, YO12 5QN

EPC Report

Energy rating

Current: 59 D | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 56 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 73 Potential: 73
Field Value
LMK KEY 0618-1024-6287-5975-4970
ADDRESS1 Flat 1
ADDRESS2 92, Scalby Road
ADDRESS3
POSTCODE YO12 5QN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2015-03-09
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001461
COUNTY
LODGEMENT DATE 2015-03-09
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 310
ENERGY CONSUMPTION POTENTIAL 195
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 54
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 794
HEATING COST POTENTIAL 505
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 106
TOTAL FLOOR AREA 75
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 22
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 22% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.49
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 1, 92, Scalby Road
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Scarborough and Whitby
POSTTOWN SCARBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-03-09 21:23:28
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100050488054
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew