Energy Performance Certificate

41, Newhall Drive, RM3 0EL

EPC Report

Energy rating

Current: 73 C | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 65 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 78 Potential: 78
Field Value
LMK KEY 0614-2818-7017-9208-6171
ADDRESS1 41, Newhall Drive
ADDRESS2
ADDRESS3
POSTCODE RM3 0EL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2018-09-08
LOCAL AUTHORITY E09000016
CONSTITUENCY E14001292
COUNTY
LODGEMENT DATE 2018-09-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 156
ENERGY CONSUMPTION POTENTIAL 89
CO2 EMISSIONS CURRENT 5.2
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 117
LIGHTING COST POTENTIAL 92
HEATING COST CURRENT 770
HEATING COST POTENTIAL 650
HOT WATER COST CURRENT 138
HOT WATER COST POTENTIAL 85
TOTAL FLOOR AREA 170
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 73
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, anthracite
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 73% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 41, Newhall Drive
LOCAL AUTHORITY LABEL Havering
CONSTITUENCY LABEL Hornchurch and Upminster
POSTTOWN ROMFORD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2018-09-10 00:18:33
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 30
LOW ENERGY FIXED LIGHT COUNT 22
UPRN 100021388951
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000007
Address display
Nation ew