Energy Performance Certificate

6, Longbrook, Chillington, TQ7 2LX

EPC Report

Energy rating

Current: 55 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 34 | Potential: 54
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 54 Potential: 54
Field Value
LMK KEY 0610-2895-7329-9394-7485
ADDRESS1 6, Longbrook
ADDRESS2 Chillington
ADDRESS3
POSTCODE TQ7 2LX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-02-15
LOCAL AUTHORITY E07000044
CONSTITUENCY E14001484
COUNTY
LODGEMENT DATE 2014-02-16
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 54
ENERGY CONSUMPTION CURRENT 418
ENERGY CONSUMPTION POTENTIAL 240
CO2 EMISSIONS CURRENT 6.1
CO2 EMISS CURR PER FLOOR AREA 74
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 105
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 704
HEATING COST POTENTIAL 526
HOT WATER COST CURRENT 151
HOT WATER COST POTENTIAL 95
TOTAL FLOOR AREA 83
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 10
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 10% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Longbrook, Chillington
LOCAL AUTHORITY LABEL South Hams
CONSTITUENCY LABEL South Devon
POSTTOWN KINGSBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2014-02-16 16:32:53
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100041202038
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000009
Address display
Nation ew