Energy Performance Certificate

Fifield, Barratts Hill, TF12 5NJ

EPC Report

Energy rating

Current: 36 F | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 F Current: 36 F 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 33 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 78 Potential: 78
Field Value
LMK KEY 0607-2897-7957-9027-4435
ADDRESS1 Fifield
ADDRESS2 Barratts Hill
ADDRESS3
POSTCODE TF12 5NJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 36
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-05-23
LOCAL AUTHORITY E06000051
CONSTITUENCY E14001493
COUNTY
LODGEMENT DATE 2013-05-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 262
ENERGY CONSUMPTION POTENTIAL 91
CO2 EMISSIONS CURRENT 20
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 5.8
LIGHTING COST CURRENT 125
LIGHTING COST POTENTIAL 128
HEATING COST CURRENT 4165
HEATING COST POTENTIAL 1292
HOT WATER COST CURRENT 315
HOT WATER COST POTENTIAL 112
TOTAL FLOOR AREA 318
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, LPG
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.67
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Fifield, Barratts Hill
LOCAL AUTHORITY LABEL Shropshire
CONSTITUENCY LABEL South Shropshire
POSTTOWN BROSELEY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-05-28 15:46:08
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 40
LOW ENERGY FIXED LIGHT COUNT 31
UPRN 100071211665
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000005
Address display
Nation ew