Energy Performance Certificate

13, East Road, Longsight, M12 5QY

EPC Report

Energy rating

Current: 13 G | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 13 G Current: 13 G 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 7 | Potential: 54
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 7 Current: 7 54 Potential: 54
Field Value
LMK KEY 0607-2870-7816-9076-4315
ADDRESS1 13, East Road
ADDRESS2 Longsight
ADDRESS3
POSTCODE M12 5QY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 13
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-09-30
LOCAL AUTHORITY E08000003
CONSTITUENCY E14001251
COUNTY
LODGEMENT DATE 2016-10-03
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 7
ENVIRONMENT IMPACT POTENTIAL 54
ENERGY CONSUMPTION CURRENT 610
ENERGY CONSUMPTION POTENTIAL 171
CO2 EMISSIONS CURRENT 22
CO2 EMISS CURR PER FLOOR AREA 122
CO2 EMISSIONS POTENTIAL 6.7
LIGHTING COST CURRENT 158
LIGHTING COST POTENTIAL 88
HEATING COST CURRENT 3471
HEATING COST POTENTIAL 1195
HOT WATER COST CURRENT 559
HOT WATER COST POTENTIAL 116
TOTAL FLOOR AREA 178
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 89
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 21
NUMBER OPEN FIREPLACES 6
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 21% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.97
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 13, East Road, Longsight
LOCAL AUTHORITY LABEL Manchester
CONSTITUENCY LABEL Gorton and Denton
POSTTOWN MANCHESTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-10-03 09:05:27
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10023043626
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display