Energy Performance Certificate

3, Braddons Hill, PL7 4RT

EPC Report

Energy rating

Current: 27 F | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 F Current: 27 F 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 27 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 86 Potential: 86
Field Value
LMK KEY 0601-2865-7471-9297-3531
ADDRESS1 3, Braddons Hill
ADDRESS2
ADDRESS3
POSTCODE PL7 4RT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 27
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-03-15
LOCAL AUTHORITY E06000026
CONSTITUENCY E14001495
COUNTY
LODGEMENT DATE 2013-03-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 456
ENERGY CONSUMPTION POTENTIAL 55
CO2 EMISSIONS CURRENT 8.1
CO2 EMISS CURR PER FLOOR AREA 87
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 102
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 1167
HEATING COST POTENTIAL 397
HOT WATER COST CURRENT 368
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 93
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 33
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Braddons Hill
LOCAL AUTHORITY LABEL Plymouth
CONSTITUENCY LABEL South West Devon
POSTTOWN PLYMOUTH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-03-18 15:55:00
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100040416314
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000009
Address display
Nation ew